    i-STAT ACTc Cartridge

    Celite activated clotting time for monitoring heparin anticoagulation therapy



    Product overview

    The i-STAT ACTc (Celite Activated Clotting Time) cartridge measures the time required for complete activation of the coagulation cascade using Celite as the activator. Unlike traditional mechanical ACT tests that detect a physical clot, the i-STAT ACTc uses a chemical measurement of thrombin presence as its endpoint. This approach has been shown to be more reliable and reproducible, with less susceptibility to external factors such as temperature, dilution, hematocrit, fibrinogen levels, and user technique.



    Expand your point-of-care testing capacity with refurbished i-STAT analyzers

    If your facility relies on the Abbott i-STAT system for point-of-care testing, Block Scientific can help you increase your testing capacity at a fraction of the cost of buying new. The Abbott i-STAT is one of Block Scientific's Centers of Excellence analyzers, which means we carry deep inventory, provide factory-level refurbishment, and back every unit with comprehensive service and support.


    Adding refurbished i-STAT 1 or i-STAT Alinity instruments to your fleet lets you deploy more analyzers across departments, satellite locations, or mobile units without the capital outlay of purchasing new. Every refurbished i-STAT from Block Scientific is thoroughly tested, calibrated, and verified to meet original manufacturer specifications before it ships.


    And when you bundle your cartridge and consumable orders with refurbished instrumentation, you get the best possible pricing on both. Complete the form on this page and your local sales rep will contact you to discuss your application.



    Clinical applications

    Used to monitor patients receiving heparin for treatment of pulmonary embolism or venous thrombosis, and for monitoring anticoagulation during catheterization, cardiac surgery, organ transplant, and dialysis. The Celite ACT is commonly used for monitoring moderate and high-level heparin therapy. Reliable, reproducible ACT results enable more accurate heparin dose adjustments.



    What does the i-STAT ACTc Cartridge measure?

    Category: Coagulation

    • ACT Celite



    Specifications

    Parameter Detail
    Compatible system i-STAT 1 System
    Sample size 40 uL
    Sample type Arterial or venous whole blood (fresh, non-anticoagulated)
    Reportable range 50 - 1,000 seconds
    Product code 03P86-25
    Quantity per box 25



    Intended use

    An in vitro diagnostic test that uses fresh, whole blood, and is useful for monitoring patients receiving heparin for treatment of pulmonary embolism or venous thrombosis, and for monitoring anticoagulation therapy in patients undergoing medical procedures.



    Frequently Asked Questions

    Both measure activated clotting time but use different activating agents. Celite (diatomaceous earth) is the traditional ACT activator and is commonly used across a range of heparin monitoring scenarios. Kaolin ACT is specifically intended for monitoring high-dose heparin in cardiovascular surgery. The choice often depends on institutional preference and the clinical protocol.

    Studies have shown the i-STAT ACT demonstrates better precision and reliability compared to some traditional ACT platforms, with less variability from external factors like temperature, sample dilution, and user technique.

    The ACTc requires fresh, non-anticoagulated whole blood from an arterial or venous draw. Do not use anticoagulated samples, as they will interfere with the clotting time measurement.



    The Abbott i-STAT is a Block Scientific center of excellence

    Block Scientific has designated the Abbott i-STAT as one of its Centers of Excellence - a select group of analyzer platforms where we provide the highest level of expertise, inventory depth, and service capability. When you purchase a refurbished i-STAT from Block Scientific, you get the benefit of more than 45 years of laboratory equipment experience, dedicated technical support, and a team that knows the i-STAT platform inside and out.


    Whether you need a single replacement unit, want to expand your POC testing footprint across multiple departments, or are looking for the best price on cartridges and consumables, Block Scientific is the partner that can make it happen at a cost that works for your budget.​​



    Ready to get started?

    Complete the form on this page and your local sales rep will contact you to discuss your application. Whether you are ordering cartridges, looking at refurbished i-STAT analyzers, or want to bundle both for the best pricing, we are here to help.

    ​​