For Business Use Only. Does Not Ship to Residential Addresses. For use inside an Analyzer, Sold Separately.
CDS Hematology Diluent for Mindray BC-2800, BC-3000, BC-3200, 20 Liters
In Stock
Product code: CDS-501-201
MPN: 501-201
Manufacturer: Clinical Diagnostic Solutions
Shipping Weight: 47.00lbs (21.32kg)
WHY CHOOSE BLOCK SCIENTIFIC?
See why in 2 mins.
CDS Hematology Diluent for Mindray BC-2800, BC-3000, BC-3200, 20 Liters
The CDS Hematology Diluent is a 20-liter, azide-free, filtered isotonic electrolyte solution for in vitro diagnostic use with Mindray™ BC-2800, BC-3000, and BC-3200 analyzers. It ensures precise blood cell counting.
Handling and Storage
- Precautions for safe handling: Use personal protective equipment required by the Laboratory.
- Measure to prevent fire: No special measures required.
- Storage requirements: Store only in the original container. Store in a cool (5 - 35 °C), dry place away from away from heat and direct sunlight.
- Further information about storage conditions: Protect from heat and direct sunlight.
Physical and Chemical Properties
Property | Value |
Physical state
| Liquid |
Color
| Colorless liquid |
Odor
| Odorless |
pH-value at 20 °C (68 °F)
| 7.5 |
Melting point
| Not determined |
Boiling point
| Not determined |
Flash point | Not applicable |
Flammability (solid, gas) | Non flammable |
Auto igniting | Product is not self-igniting. |
Danger of explosion | Product does not present an explosion hazard. |
Vapor density | Not applicable |
Density at 20 °C (68 °F) | 1 g/mL |
Solubility in water | Completely soluble |
First Aid Measures
General advice
Consult a physician.
Show this safety data sheet to the doctor in attendance. Move out of dangerous area.
If inhaled
If breathed in, move person into fresh air. If not breathing, give artificial respiration. Consult a physician.
In case of skin contact
Wash off with soap and plenty of water. Consult a physician.
In case of eye contact
Rinse thoroughly with plenty of water for at least 15 minutes and consult a physician.
If swallowed
Never give anything by mouth to an unconscious person. Rinse mouth with water. Consult a physician.
Most important symptoms and effects, both acute and delayed
None
Indication of any immediate medical attention and special treatment needed
No data available
Firefighting Measures
- Suitable extinguishing agents
Dry chemical, carbon dioxide (CO2), water spray or regular foam.
- Caution: CO2 will displace air in confined spaces and may cause an oxygen-deficient atmosphere. -
Special hazards arising from the substance or mixture
There are no unique chemical or reactivity hazards that would impact firefighting decisions due to the chemicals in this product.
Accidental Release Measures
-
Personal precautions, protective equipment and emergency procedures
Minimize exposure by using appropriate personal protective equipment as listed in Section 8. Stop leak if possible. Keep unprotected people away. - Environmental precautions
Prevent liquid from entering sewage system, storm drains, surface waters, and soil. - Methods and material for containment and cleaning up
Block small volumes of spilled or spattered product with paper towels or similar materials.
- Contain larger spills by placing absorbants around the outside edges of the spill. Absorb with any material Suitable for water-based liquids - e.g. paper towels, universal sorbents, sand, diatomite, sawdust, etc. - Clean the affected area. Suitable cleaners are:
- Detergent or similar cleansing agent.
Dispose of spilled and contaminated material in accordance with Federal, State, and Local regulations. See Section 13 for information that may impact disposal of materials contaminated with this product.
Specifications
| UOM | Each |
Brand | Clinical Diagnostic Solutions |
Restricted Class | Normal |
Type | Diluent |
Physical Form | Liquid |
Ph | 7.5 |
Color | Clear |
Size | 20 Liter |
Related Documents
CDS Hematology Diluent for Mindray BC-2800, BC-3000, BC-3200 Safety Data Sheet