    The Beckman Coulter DxM 1040 MicroScan™ WalkAway ID/AST System is a state-of-the-art microorganism identification (ID) and antimicrobial susceptibility testing (AST) system designed to provide rapid, accurate results. The system’s performance has been recognized with the IMV ServiceTrack™ Award for Best System Performance in the AST/ID category, demonstrating its exceptional value in clinical microbiology laboratories worldwide.

    The Beckman Coulter DxM 1040 MicroScan™ WalkAway ID/AST System is a highly efficient, automated microbiology solution that delivers rapid, accurate results for microorganism identification and antimicrobial susceptibility testing. With its high throughput, advanced resistance detection, and user-friendly design, it is an invaluable tool for clinical laboratories aiming to improve diagnostic efficiency and support effective patient therapy.

    Panel capacity 40 MicroScan panels with 96 wells each of any type compatible with the incubator environment; up to eight panel towers with five panels each 




    ACCURACY MATTERS​

    Preventing the spread of antimicrobial-resistant (AMR) bacteria within hospitals and communities requires correct identification of AMR pathogens as quickly as possible. MicroScan systems use direct MICs for the detection of emerging resistance, providing accurate and timely results without reliance on historical data.

    The DxM 1040 MicroScan WalkAway system uses real MIC technology to provide accurate results that laboratories need to operate efficiently.

    Request a quote now



    Key Features

      Rapid Microorganism Identification and Susceptibility Testing:

      • 600 samples per hour: The DxM 1040 MicroScan WalkAway system offers high throughput with the ability to process up to 600 samples per hour, significantly improving laboratory efficiency and reducing turnaround time.
      • Direct MIC Detection: It accurately detects emerging resistance such as carbapenemase-resistant Enterobacteriaceae (CRE), ESBL, MRSA, VRE, and other tough pathogens, making it essential for global health surveillance and infection control.


      Advanced Resistance Detection:

      • The system includes advanced resistance detection for difficult pathogens, ensuring you can identify resistance patterns early, which is crucial for effective patient therapy.
      • It has the ability to detect carbapenemase-resistant organisms, a key focus for addressing global antimicrobial resistance issues.


      Fast Turnaround Time:

      • With enhanced electronics and advanced vacuum pump technology, the system offers faster target exchange time, resulting in quicker time-to-result and reducing operational burden.


      Low Maintenance:

      • Integrated ion source cleaning, controlled by a simple mouse click, eliminates the need for vacuum release, ensuring minimal downtime and ongoing lab efficiency.


      Optimized Workflow:

      • LabPro MR software enables customizable data management, helping labs tailor the system’s performance to their specific needs. The software automates atypical result detection, directing technicians to the most appropriate actions based on customized institutional procedures.
      • The system is capable of processing conventional, rapid, and specialty panels simultaneously on a single automated platform, providing comprehensive and flexible testing.


      Compact Design:

      • The DxM 1040 MicroScan WalkAway is a benchtop solution with a small footprint, making it ideal for labs with space limitations. It weighs 376 lbs and features a compact design without compromising performance.


      User-Friendly Interface:

      • The system’s 2-line, 20-character vacuum fluorescence display and front-panel controls make it easy to use, while the PC keyboard and LabPro software enable intuitive system navigation and data management.


      Performance and Capacity:

      • Panel Capacity: The system accommodates 40 MicroScan panels with 96 wells each for ID/AST testing.
      • Incubation Temperature Stability: Ensures consistent incubation at 35°C ±1°C, vital for accurate testing and reliable results.
      • Reagent and Oil Dispense Volume: Reagent dispense volume ranges from 15 to 90 µl depending on the reagent, ensuring precise sample preparation.


      Physical and Environmental Specifications:

      • Dimensions: 29" H x 38.5" W x 34" D
      • Weight: 376 lbs
      • Power Requirements: 220/230/240 VAC, 50/60 Hz with overcurrent protection and circuitry for fail-safe operation.
      • Operating Conditions: Temperature: 59°F to 80.6°F, Humidity: 30% to 80% RH (non-condensing).


      Safety and Compliance:

      • The system complies with various safety standards, including IEC 61010-1, EN 61010-1, and UL 61010-1, ensuring reliable operation and safety in clinical settings.


      Applications:

      • Microorganism Identification: The DxM 1040 MicroScan WalkAway system is ideal for identifying a wide range of pathogens, including bacteria and fungi, in clinical microbiology labs.
      • Antimicrobial Susceptibility Testing (AST): The system provides rapid, accurate AST results, helping clinicians make informed decisions about appropriate antibiotic therapy.
      • Hospital and Clinical Labs: In hospitals and clinical labs, this system is essential for infection control and antimicrobial stewardship, ensuring patients receive the most effective treatment based on accurate and timely pathogen identification and resistance profiling.




      Experience the Benefits

      Streamlined Panel Workflow

      Simultaneous Panel Processing

      External LED Status Indicators

      Front Panel Controls and Display

      Compact Benchtop Design



      Get answers right the first time!

      Accurate drug-bug performance 
      the fastest clinically significant drug-bug limitations of any automated ID/AST system result in fewer repeat and confirmatory tests. 

      Streamlined workflow 
      Prompt system streamlines workflow and supports testing for the majority of the routine samples. 

      Real-time alerts 
      LabPro Alert automated detection of atypical results for quick recognition and reporting.

      Powerful reporting 
      MIC and susceptibility results that correlate with classical broth microdilution and disk diffusion in the most trusted way. 



      Backed by more than 40 years of ID/AST testing experience, MicroScan microbiology systems improve workflow by minimizing the need for confirmatory retesting and providing accurate, first-time results for laboratories of every size.​



      Specifications​​

      Physical DxM 1040 MicroScan WalkAway: 29" H × 38.5" W × 34" D; 376 lbs
      Color: White with gray trim
      Interface connector: RJ-45 carrying RS-232 protocol
      Power Requirements Line voltage: 100/120/220/230/240 VAC (selected by internal jumpers)
      Line frequency: 50/60 Hz ±5%
      Line current: 9 A (nominal), 11 A (max) @ 100/120 VAC; 4.5 A (nominal), 5.5 A (max) @ 220/230/240 VAC
      Power loss protection: Fail-safe circuitry with auto restart
      Heat generation: 3,400 BTU/hour
      Recommended Laboratory Environmental Conditions Temperature (operating): 59°F to 80.6°F
      Humidity: 30% to 80% RH (no condensation)
      Safety Requirements Ground impedance: 0.1 Ω (max)
      Dielectric withstand voltage: No breakdown at 1,400 VDC for 1 min
      Leakage current: <0.5 mA
      Removable power cord: 3-conductor, 14 AWG (100/120 V) / 16 AWG (220/230/240 V)
      Interlocks: Panel access door, reagent drawer, service hatch
      Power plug: NEMA 5-15P / IEC 60320 C14
      Standards: IEC 61010-1, EN 61010-1, CAN/CSA C22.2 No. 61010-1-12, UL 61010-1, IEC 61010-2-081, EN 61010-2-081, CAN/CSA C22.2 No. 61010-2-081, UL 61010-2-081, IEC 61010-2-101, EN 61010-2-101, CAN/CSA C22.2 No. 61010-2-101, UL 61010-2-101
      Overcurrent Protection Fusing: Primary fuses F1 & F2, IEC 5×20 mm slow-blow type, 250 V rated
      12 A (100/120 V) / 6.3 A (220/230/240 V)
      Light Source Tungsten-halogen lamp, 50 W, 12 V
      Tungsten-halogen lamp, TL 2½, 15 W, 10.5 V
      Display 2-line, 20-character alphanumeric vacuum fluorescence display
      Temperature Control Set by computer at 35°C ±1°C
      Bar Code Code 39 standard conformance
      Performance DxM 1040 capacity: 40 MicroScan panels (96 wells each), up to 8 panel towers (5 panels/tower)
      Incubation temperature stability: ±1°C
      Reagent type capacity: 10 total
      Reagent dispense volume: 15–90 μL
      Oil dispense volume: 60–150 μL
      Operator interface: Front-panel controls + PC keyboard, monitor, LabPro software