    Siemens Healthcare Diagnostics

    Offers a fully equimolar, automated total 25(OH) vitamin D (~100% D2 and D3) assay* employing a proprietary monoclonal with minimal 1.1% 3-epi-25(OH) vitamin D3 cross-reactivity aligned to the ID-LC/MS/MS 25(OH)vitamin D Reference Method Procedure (RMP)1,2, the reference procedure for the Vitamin D Standardization Program (VDSP). Laboratories can meet increased testing demands by consolidating vitamin D testing on a fully automated, high-throughput immunoassay system.


    Advantages

    • Confidence in results through alignment to the 25(OH)vitamin D RMP*1,2
    • Consistent and clinically accurate patient results with the equimolar total measurement of 25(OH)vitamin D2 and D3
    • Vitamin D can be combined with routine, stat, and specialty assays without compromising time – results are provided in 18 minutes with a throughput of 240 tests per hour
    • Proprietary monoclonal antibody provides lot-to-lot consistency
    • Reduced risk of confounding assessment with minimal cross-reactivity with 3-epi-25(OH)vitamin D3(1.1%)
    • A broad dynamic assay range (4.2–150 ng/mL) and on-board dilution – accommodates variety of patient results with minimal intervention.
    • Total measurement of 25(OH)vitamin D2 and D3
    • Good precision – 4.2% - 11.9% CV
    • Traceable to the ID-LC/MS/MS 25(OH)vitamin D RMP
    • Results in as little as 18 minutes (ADVIA Centaur® XP)


     

    ADVIA Centaur Vitamin D Total Assay

    Product Code

    10699201 (100 tests), 10699533 (500 tests)

    Sample Type

    Serum / Plasma (EDTA, lithium-heparin, sodium heparin)

    Sample Volume

    20 µL

    Assay Range

    4.2 - 150 ng/mL

    Limit of Quantitation

    4.2 ng/mL

    Calibration Interval

    28 days

    Onboard Stability

    28 days




    Free, Simple Tactics to Lower Your Cost Per Test